A Study on the Way of Maintenance of Sanitary Environment in Medical Facilities : Part2-The actual status and countermeasures of airborne microbe contamination in waiting rooms
-
- Yanagi U
- National Institute of Public Health
-
- Kagi Naoki
- National Institute of Public Health
-
- Ikeda Koichi
- National Institute of Public Health
-
- Nishimura Naoya
- Shibaura Institute of Technology
-
- Yoshino Hiroshi
- Tohoku University
-
- Obata Michio
- Building Management Education Center
-
- Saito Hideki
- Building Management Education Center
-
- Saito Keiko
- Building Management Education Center
-
- Kamakura Ryota
- Building Management Education Center
Bibliographic Information
- Other Title
-
- 病院施設における室内環境の衛生管理に関する研究 : 第2報-外来待合室内浮遊微生物汚染の実態とその対策方法
- ビョウイン シセツ ニ オケル シツナイ カンキョウ ノ エイセイ カンリ ニ カンスル ケンキュウ ダイ2ホウ ガイライ マチアイ シツナイ フユウ ビセイブツ オセン ノ ジッタイ ト ソノ タイサク ホウホウ
Search this article
Description
This paper reports the measurement results of indoor airborne microbial contamination in 9 hospital waiting rooms. Based on the measurement results, the design method on an air conditioning system to carry out improvement in the indoor air quality, especially in airborne microbes, was discussed from the view point of reducing the risk of mutual infection in hospitals. The main findings obtained from this study are as follows. Since the major sources of airborne fungi in waiting rooms are from the outdoor, it is important to appropriately maintain hospital environment in order to prevent the multiplication of fungi. On the other hand, as the major sources of the airborne bacteria in waiting rooms are patients themselves, it is necessary to reduce the mutual infection risk in hospitals by controlling indoor airborne bacteria contamination. Since the present performance of the air conditioning system is inadequate for filtrating and diluting indoor airborne microbes during reception period of a waiting room, indoor airborne bacteria concentration may become remarkably high. From the standpoint of reduction of mutual infections, it is important to install high performance equipment.
Journal
-
- Transactions of the Society of Heating,Air-conditioning and Sanitary Engineers of Japan
-
Transactions of the Society of Heating,Air-conditioning and Sanitary Engineers of Japan 33 (141), 9-17, 2008
The Society of Heating, Air-Conditioning & Sanitary Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282681521611392
-
- NII Article ID
- 110007996763
-
- NII Book ID
- AN00065706
-
- ISSN
- 24240486
- 0385275X
-
- NDL BIB ID
- 9743527
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- CiNii Articles
-
- Abstract License Flag
- Disallowed