Preparation of a Small Acute-phase Cerebral Infarction Phantom for Diffusion-weighted Imaging
-
- Takahashi Masahiko
- Central Radiology Department, Isesaki Municipal Hospital
-
- Hashimoto Maiko
- Central Radiology Department, Isesaki Municipal Hospital
-
- Uehara Masumi
- Graduate School of Radiological Technology, Gunma Prefectural College of Health Science
Bibliographic Information
- Other Title
-
- 拡散強調画像用急性期微小脳梗塞ファントムの作製
- カクサン キョウチョウ ガゾウヨウ キュウセイキ ビショウノウ コウソク ファントム ノ サクセイ
Search this article
Description
<p>The present study aimed to prepare a small acute-phase cerebral infarction phantom made of gelatin and sucrose to simulate brain parenchymal cells, and a phantom made of collagen peptides and sucrose to simulate cerebral infarction for diffusion-weighted imaging (DWI). During the preparation of gelatin and sucrose mixture (17.0 wt% gelatin, 20.0 wt% sucrose), a cylindrical wooden bar was placed in the center of the phantom and covered with a heat-shrinkable film to ensure space remained after gelling. A mixed solution composed of collagen peptide and sucrose (16.0 wt% collagen peptide, 27.5 wt% sucrose) was then enclosed within the space. The T2 relaxation time and apparent diffusion coefficient (ADC) of the phantom were set equal to those observed in actual patients with acute-phase cerebral infarction. The mixture was selected based on the signal intensity of both the healthy brain tissue and that subjected to acute cerebral infarction, such that no contrast was observed during T2-weighted imaging (T2WI). T2WI and DWI were performed using a 1.5 T scanner. Although contrast between the mixed gel and mixed solution was obscure on T2WI, cerebral infarction was clearly visible on DWI. However, the phantom exhibited mono-exponential changes in the ADC value at b values of 0 and 1,000 (s/mm2), and was affected by the proton density and T1 value depending on the imaging condition.</p>
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 74 (6), 531-538, 2018
Japanese Society of Radiological Technology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282763015243776
-
- NII Article ID
- 130007397902
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- NDL BIB ID
- 029125216
-
- PubMed
- 29925747
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed