- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
USEFULNESS OF THE FORCED OSCILLATION TECHNIQUE IN THE DIAGNOSIS OF COUGH VARIANT ASTHMA WITH PROLONGED OR CHRONIC COUGH
-
- Kato Kan
- Department of Internal Medicine, Ooizumi Health Cooperative Hospital Department of Internal Medicine, Tokyo Kensei Hospital Sapporo Cough Asthma and Allery Center
-
- Tanaka Hiroshi
- Idaimae Minami Yojyo Naika Sapporo Cough Asthma and Allery Center
Bibliographic Information
- Other Title
-
- 遷延性・慢性咳嗽を呈した咳喘息の診断における強制オシレーション法の有用性
- センエンセイ ・ マンセイ セキソウ オ テイシタ セキ ゼンソク ノ シンダン ニ オケル キョウセイ オシレーションホウ ノ ユウヨウセイ
Search this article
Description
<p>Background: Usefulness of carrying out the reversibility test after inhaling bronchodilator by forced oscillation technique (FOT) in addition to spirometry was investigated in the diagnosis of bronchial asthma (BA), cough variant asthma (CVA) and allergic rhinitis (AR) with prolonged or chronic cough.</p><p>Methods: The subjects were the 622 patients at Idaimaeminamiyojo Clinic in Sapporo who complained cough over three weeks, and underwent bronchial reversibility test with salbutamol by using spirometry and FOT. We divided them into 5 groups; BA, BA+AR, CVA, CVA+AR, AR, and examined their lung functions.</p><p>Results: The mean of improvement of FEV1 after inhalation of salbutamol was significantly different (p<0.001); 465ml (26%) of BA, 136ml (5.5%) of CVA, and 44ml (1.6%) of AR. However, in CVA, the mean reversibility value was not over the diagnostic criteria of BA; 200ml (12%). Improvement of respiratory resistant at 5Hz (R5) using FOT in BA/CVA were 25.7%/24.1%, and significantly higher (p<0.001) than that in AR, and these results were alike even in cases accompanied by AR; BA+AR, CVA+AR, and AR. AUC value in the ROC curve for diagnosis of CVA from AR with R5 was 0.870, and highest among with R5, R20, R35 and Fres. When the cut off value of R5 improvement was 15%, sensitivity was 74% and specificity was 81%.</p><p>Conclusion: It was suggested that the additional bronchial reversibility test using FOT may be useful especially in the diagnosis of cough variant asthma where the reversibility in spirometry alone is not sufficient.</p>
Journal
-
- Japanese Journal of Allergology
-
Japanese Journal of Allergology 67 (6), 759-766, 2018
Japanese Society of Allergology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282763022282112
-
- NII Article ID
- 130007405850
-
- NII Book ID
- AN00012583
-
- ISSN
- 13477935
- 00214884
-
- NDL BIB ID
- 029150623
-
- PubMed
- 30022785
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- PubMed
- CiNii Articles
-
- Abstract License Flag
- Disallowed