Two-hour Fireproof Performance of Cross Laminated Timber (CLT) Covered with Fire-retardant Impregnated Wood
-
- Harada Toshiro
- Forestry and Forest Products Research Institute
-
- Kamikawa Daisuke
- Forestry and Forest Products Research Institute
-
- Miyatake Atsushi
- Forestry and Forest Products Research Institute
-
- Shindo Kenta
- Forestry and Forest Products Research Institute
-
- Hattori Nobuaki
- Tokyo University of Agriculture and Technology
-
- Ando Keisuke
- Tokyo University of Agriculture and Technology
-
- Miyabayashi Masayuki
- T. E. Consulting Inc.
Bibliographic Information
- Other Title
-
- 難燃処理木材で被覆した直交集成板(CLT)の<b>2</b>時間耐火性能
- 難燃処理木材で被覆した直交集成板(CLT)の2時間耐火性能
- ナンネンショリ モクザイ デ ヒフク シタ チョッコウ シュウセイバン(CLT)ノ 2ジカン タイカ セイノウ
Search this article
Description
<p>In order to develop 2-hour-fireproof cross laminated timber (CLT) floor and wall structures, covering them with wood impregnated with fire-retardant agent was studied. In the fire test of the CLT wall specimen, two layers of fire-retardant impregnated wood (Cryptomeria japonica D. Don) were alternately laminated with screws to the load-bearing CLT and a fire test was conducted for 2 hours. The total thickness of the covering material was 90 mm. However, the CLT burned due to early drop-off of the top layer and shrinkage of the second layer, and the wall specimen did not show 2-hour fire-resistance performance. Based on this test result, in the fire test of the floor, the covering material was specified as a fire-retardant impregnated wood panel of three layers of 30 mm thick treated wood and a 10 mm thick untreated wood layer laminated and bonded together with adhesives. The panels were joined by two types of spline made of fire-retardant impregnated wood, and were attached to the CLT with screws. The screw holes were filled with untreated wood. In the 2 hour-fire tests of the floor specimens, flames died out and charring stopped in the covering layer. This result shows that covering with fire-retardant impregnated wood panels makes the CLT 2-hour fireproof.</p>
Journal
-
- Mokuzai Gakkaishi
-
Mokuzai Gakkaishi 65 (1), 46-53, 2019-01-25
The Japan Wood Research Society
- Tweet
Details 詳細情報について
-
- CRID
- 1390282763094990080
-
- NII Article ID
- 130007584696
-
- NII Book ID
- AN00240329
-
- ISSN
- 18807577
- 00214795
-
- NDL BIB ID
- 029480817
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed