- Discussion on Difference between 3 Cup and Ultrasonic Anemometers of the Obtained Statistical Values to be Used for Wind Environment Assessment
- カゼ カンキョウ ヒョウカ ノ タメ ノ サンバイガタ フウソクケイ ト チョウオンパガタ フウソクケイ ニ ヨル トウケイリョウ ノ サ ノ ケントウ
- 公開日
- 2018-07-31
- DOI
-
- 10.5359/jwe.43.91
- 公開者
- 一般社団法人 日本風工学会
この論文をさがす
説明
The criterion for wind environment assessment by Wind Engineering Institute Co., Ltd. is based on the relation between the mean wind speeds measured by 3 cup anemometers and the surrounding condition. Recently, ultrasonic anemometers with lower cost and higher performance has become popular and taken place of 3 cup anemometers; 3-cup anemometers respond to the wind speed change slowly for lower wind speeds while they tend to over-rotate for higher wind speeds due to the effect of inertia force. Considering this circumstances, the present paper investigates the difference between 3 cup anemometer and ultrasonic anemometer for the measured values. Based on the results, we propose a correction method for converting the measured values by 3 cup anemometers to those by ultrasonic anemometers.
収録刊行物
-
- 日本風工学会論文集
-
日本風工学会論文集 43 (3), 91-99, 2018-07-31