- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Assessing the Effect of Laboratory Environment on Sample Contamination for I-129 Accelerator Mass Spectrometry
-
- MATSUMURA Masumi
- Tandem Accelerator Complex, University of Tsukuba
-
- SASA Kimikazu
- Tandem Accelerator Complex, University of Tsukuba
-
- MATSUNAKA Tetsuya
- Institute of Nature and Environmental Technology, Kanazawa University
-
- SUEKI Keisuke
- Tandem Accelerator Complex, University of Tsukuba
-
- TAKAHASHI Tsutomu
- Tandem Accelerator Complex, University of Tsukuba
-
- MATSUZAKI Hiroyuki
- The University Museum, The University of Tokyo
Search this article
Description
<p>Environmental contaminations of 129I were continuously monitored in various sample preparation rooms for accelerator mass spectrometry at the University of Tsukuba. Monitoring of 129I was performed in the rooms used for the treatment of samples in the past, in order to compare with the results obtained in the sample preparation rooms. Ambient levels of atmospheric 129I in each room were estimated from the measured concentrations in the alkali trap solutions. This article reports the results of one year of monitoring the temporal changes of stable iodine (127I) and 129I contamination rates in the alkali trap solutions. It was found that 129I contamination rates were lower than approximately 104 atoms cm−2 day−1 in the rooms where ether no samples or only samples with environmental background levels of 129I were handled. Values from 104 to 105 atoms cm−2 day−1 were recorded in another room where environmental samples, such as the samples derived from nuclear power plant accidents, were treated. Higher levels of 129I, ranging from 106 to 107 atoms cm−2 day−1, were recorded in rooms used for treating neutron-activated iodine. The experimental results show that the 129I level depended on the 129I sample-preparation histories for the respective rooms. It is possible to estimate the 129I contamination risk from the atmosphere to the samples by knowing the 129I level in the preparation room.</p>
Journal
-
- Analytical Sciences
-
Analytical Sciences 36 (5), 631-636, 2020-05-10
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390285300156488192
-
- NII Article ID
- 130007840925
-
- NII Book ID
- AA10500785
-
- ISSN
- 13482246
- 09106340
-
- HANDLE
- 2241/0002001707
-
- NDL BIB ID
- 030457253
-
- PubMed
- 32092734
-
- Web Site
- https://tsukuba.repo.nii.ac.jp/records/2001707
- http://id.ndl.go.jp/bib/030457253
- https://ndlsearch.ndl.go.jp/books/R000000004-I030457253
- https://link.springer.com/content/pdf/10.2116/analsci.20SBN05.pdf
- https://link.springer.com/article/10.2116/analsci.20SBN05/fulltext.html
- https://www.jstage.jst.go.jp/article/analsci/36/5/36_20SBN05/_pdf
-
- Text Lang
- en
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- IRDB
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- KAKEN
- OpenAIRE
-
- Abstract License Flag
- Disallowed