Evaluation of Chloride Ion Concentration and pH on Depassivation of Steel Rebar in Concrete Investigated by Electrochemical Impedance Measurement of Probe Electrodes

DOI DOI Web Site Web Site Web Site View 1 Remaining Hide 3 Citations 7 References Open Access
  • Hoshi Yoshinao
    Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science Department of Pure and Applied Chemistry, Graduate School of Science and Technology, Tokyo University of Science
  • Watanabe Shuhei
    Department of Pure and Applied Chemistry, Graduate School of Science and Technology, Tokyo University of Science
  • Tokieda Hiroyuki
    Department of Pure and Applied Chemistry, Graduate School of Science and Technology, Tokyo University of Science
  • Shitanda Isao
    Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science Department of Pure and Applied Chemistry, Graduate School of Science and Technology, Tokyo University of Science Research Institute for Science & Technology, Tokyo University of Science
  • Itagaki Masayuki
    Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science Department of Pure and Applied Chemistry, Graduate School of Science and Technology, Tokyo University of Science Research Institute for Science & Technology, Tokyo University of Science

Bibliographic Information

Other Title
  • プローブ電極の電気化学インピーダンス測定によるコンクリート内鉄筋の脱不働態化に対する塩化物イオン濃度とpHの評価
  • プローブ電極の電気化学インピーダンス測定によるコンクリート内鉄筋と脱不働態化に対する塩化物イオン濃度とpHの評価
  • プローブ デンキョク ノ デンキ カガク インピーダンス ソクテイ ニ ヨル コンクリート ナイ テッキン ト ダツフドウタイカ ニ タイスル エンカブツ イオン ノウド ト pH ノ ヒョウカ

Search this article

Description

<p>Relationship between chloride ion concentration and pH on depassivation of steel rebar embedded in concrete was investigated by a two frequencies impedance measurement using probe electrodes. A saturated calcium hydroxide solution was used for the electrolyte solution as simulated concrete pore solution. The pair of probe electrodes, which simulates the steel rebar, was immersed in the electrolyte solution prepared by arbitrary concentration of chloride ions, and the two frequencies impedance measurement was performed. Air was supplied to the electrolyte solution in order to simulate the neutralization of concrete during the measurement. The charge transfer resistance related to electrode/solution interface, Rct, were estimated from the two frequencies impedance measurement of probe electrodes in each electrolyte solution, demonstrating that the Rct was drastically decreased with decreasing the pH of electrolyte solution, namely, the depassivation on steel rebar. The corrosion conditions of steel rebar were categorized as “passive state”, “depassivation”, and “corrosion” based on the changes of monitoring of Rct and pH in each electrolyte solution, and these results were plotted on the two dimensional diagram composed of chloride ion concentration and pH of electrolyte solution. The conditions for depassivation of passive film on steel rebar were discussed.</p>

Journal

  • Corrosion Engineering

    Corrosion Engineering 68 (11), 303-308, 2019-11-10

    Japan Society of Corrosion Engineering

Citations (3)*help

See more

References(7)*help

See more

Report a problem