Optimization of Echo Train Length in Non-contrast Enhanced MR Angiography for Clinical Examination of the Calf Arteries
-
- Fujimoto Ayako
- Department of Radiology, Maizuru Kyosai Hospital Tohoku University Graduate School of Medicine
-
- Aoba Minami
- Tohoku University Graduate School of Medicine Department of Radiology, Akita Kousei Medical Center
-
- Machida Yoshio
- Tohoku University Graduate School of Medicine
Bibliographic Information
- Other Title
-
- 膝下三分枝を対象とした非造影 MRA における臨床に向けたエコートレイン数の最適化
- 臨床技術 膝下三分枝を対象とした非造影MRAにおける臨床に向けたエコートレイン数の最適化
- リンショウ ギジュツ ヒザモト サン ブンシ オ タイショウ ト シタ ヒゾウエイ MRA ニ オケル リンショウ ニ ムケタ エコートレインスウ ノ サイテキカ
Search this article
Description
<p>Purpose: Non-contrast magnetic resonanse angiography (MRA) using the three-dimensional electrocardiogram-synchronized fast spin echo method uses systolic and diastolic arterial signal differences. The method relies on the flow void signal of the arterial flow because of dephasing during systole. However, depiction of slow flow such as that in a calf artery was degraded because of insufficient dephasing during systole. In this study, we optimized echo train length (ETL) using a flow phantom and normal volunteers for clinical examination of the calf arteries. Methods: Flow phantom and normal volunteer images were obtained with various ETLs (40, 50, 60, and 70). An averaged profile across the tube in the phantom was used for detailed investigation of flow dephasing. Visual evaluation was performed and signal intensity change along vessels was measured using normal volunteer images. Comparison with peak systolic velocity (PSV) measured using ultrasound equipment was also conducted. Results: Results of the flow phantom and normal volunteer study indicated that the overall depictability was improved with ETL 60 and 70, which was higher than the standard value. Additionally, the visualization of the peroneal artery with low PSV of ETL 70 had better depictability than ETL 60. Conclusion: This study suggested that ETL 70 might be better for clinical examination of the calf arteries.</p>
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 76 (7), 689-698, 2020
Japanese Society of Radiological Technology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390285300176962304
-
- NII Article ID
- 130007878289
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- NDL BIB ID
- 030577123
-
- PubMed
- 32684561
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- PubMed
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed