COMPARISON BETWEEN FINISH DAMAGE LEVEL AND STORY DEFORMATION OF WOODEN HOUSE AFTER EARTHQUAKE
-
- INOUE Ryo
- Graduate School of Advanced Sci. and Eng., Hiroshima Univ.
-
- MORI Takuro
- Graduate School of Advanced Sci. and Eng., Hiroshima Univ.
-
- TANAKA Kei
- Faculty of Sci. and Tec., Oita Univ.
-
- TAKI Yutaka
- NIKKEN SEKKEI Ltd.
-
- ISODA Hiroshi
- RISH, Kyoto Univ.
Bibliographic Information
- Other Title
-
- 木造住宅の地震時仕上げ損傷状況と経験層間変形の関係
Search this article
Description
<p>In order to continue using wooden houses after the earthquake, it is necessary to accurately judge the damage level and make appropriate repairs. Therefore, an evaluation index for estimating the experience deformation from the damage situation of interior and exterior finishes is proposed. When evaluating the finish damage level of the static resisting wall test and the shaking table test, it was found that internal finish damage was more accurately estimated than external ones. When the cloth was torn along the gypsum board joint, the deformation was classified as D2 level damage.</p>
Journal
-
- AIJ Journal of Technology and Design
-
AIJ Journal of Technology and Design 26 (64), 917-922, 2020-10-20
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390286426516680832
-
- NII Article ID
- 130007928338
-
- NII Book ID
- AN10531441
-
- ISSN
- 18818188
- 13419463
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed