Precise alignment monitor based on an optical frequency comb (5th report)
-
- Kume Tatsuya
- High Energy Accelerator Research Organization
-
- Yasuda Hiromasa
- The University of Tokyo
-
- Mibe Tsutomu
- High Energy Accelerator Research Organization
-
- Michihata Masaki
- The University of Tokyo
-
- Takahashi Satoru
- The University of Tokyo
Bibliographic Information
- Other Title
-
- 光周波数コムを用いた高精度アライメントモニター(第5報)
- Calibration of the pulse repetition frequency of an optical frequency comb compressed by an etalon
- エタロンで圧縮された光周波数コムのパルス繰返し周波数の校正
Abstract
<p>We aim to monitor several micro-meters of alignment changes for an object with diameter of 600 mm and height of 750 mm for a period longer than several months in a high magnetic field and vacuum by using a length measurement grid. It consists of multiple measurement paths of absolute distance interferometers introduced into the object by using optical fibers. It refers a pulse interval of an optical frequency comb compressed by an etalon. We calibrated the compressed pulse interval with relative uncertainty of several ppm (k = 2). Here, we calibrate it in a frequency domain aiming for higher reliability.</p>