EXPERIMENTAL STUDY ON STRUCTURAL PERFORMANCE EVALUATION OF COLUMN-TO-<i>NUKI</i> CONNECTION IN TRADITIONAL TIMBER SHRINES AND TEMPLES

  • MURAI Satsuki
    NISSOKEN Architects / Engineers
  • MIYAMOTO Mitsuhiro
    Program in Arch., Civil and Environmental Eng., Dept. of Eng. and Design, Faculty of Eng. and Design, Kagawa Univ.

Bibliographic Information

Other Title
  • 社寺建築における柱貫接合部の構造性能評価に関する実験的研究

Search this article

Abstract

<p>Column-to-nuki connections are important to evaluate the seismic performance of traditional timber shrines and temples. These connections include several joint types, one of which is the oblique scarf joint. However, few previous studies have examined the column-to-nuki connections of the oblique scarf joint and no design equations exist for them. Thus, this study aims to evaluate the structural performance of column-to-nuki connections in traditional timber shrines and temples based on the full-scale tests. It is shown that the theoretical value of 50 % continuous nuki can safely evaluate the experimental value of the oblique scarf joint.</p>

Journal

References(2)*help

See more

Details 詳細情報について

Report a problem

Back to top