反射光を利用した高圧相平衡の測定

書誌事項

タイトル別名
  • Measurement of Phase Equilibrium at High-Pressure Using Reflected Light
  • ハンシャコウ オ リヨウ シタ コウアツソウ ヘイコウ ノ ソクテイ

この論文をさがす

抄録

<p>In this article, the phase equilibrium measurement based on the synthetic method under high pressure using reflected light is presented. The vapor phase separation point was determined by measuring the displacement of the piston with a laser displacement meter using the rapid volume change caused by the vapor phase generation. The liquid phase separation point was determined by measuring the reflected light intensity with a light sensor using the light scattering caused by the liquid phase generation. This method was successful in reducing human error.</p>