部分層に履歴型ダンパーを設置した制震構造のDs値、エネルギー吸収性能および主架構の1次固有周期

書誌事項

タイトル別名
  • Ds-VALUE, ENERGY ABSORPTION AND PRIMARY NATURAL PERIOD OF THE MAIN FRAME FOR A DAMPING STRUCTURE WITH HYSTERETIC DAMPERS IN PARTIAL STORIES
  • Effect of mass ratio and stiffness ratio between stories with and without dampers, number of stories ratio, and ground classification based on energy balance
  • エネルギーの釣合いに基づくダンパー設置層と非設置層の質量比、剛性比、層数比および地盤種別の影響

抄録

<p>This paper investigates the effects of mass/stiffness ratio between stories with and without dampers, and the stories ratio on the Ds-value, which expresses the response-reduction effect, and the dampers’ energy absorption for a medium/low-rise building, aiming to contribute to the actual design of vibration control structures with dampers installed in partial stories. It also determines realistic constraints on the maximum shear coefficient and the maximum inter-story deformation angle of a 1-layer with respect to the design input energy, and propose a simple practical formula for the primary natural period of a main frame that copes with these constraints.</p>