STATIC LOADING TESTS OF HIGH STRENGTH CONCRETE SIDEWALLS FAILING IN FLEXURE

  • KATO Daisuke
    Dept. of Architecture and Civil Engineering Faculty of Engineering, Niigata University
  • IIZAWA Yudai
    Graduate School of Science and Technology, Niigata University
  • KATORI Miki
    Graduate School of Science and Technology, Niigata University

Bibliographic Information

Other Title
  • 高強度コンクリートを用いた曲げ降伏するRC造袖壁の静加力実験

Abstract

<p>Objectives of this study were to examine deformation capacities of reinforced concrete columns with side walls failing in flexure. Deformation capacities mainly depend on the compressive performance of the edge region of the side wall. From this view point subjected axial load and confinement of the edge region of the side wall were varied. For this purpose static loading tests of side wall specimens were conducted using high strength concrete. Drift angles calculated using some evaluation equations were compared with observed ultimate drift angles and found to be not conservative for specimens with high strength concrete. Currently used design indecies expressing deformation capacities (member rank) were also compared with test results.</p>

Journal

Citations (1)*help

See more

Details 詳細情報について

Report a problem

Back to top