- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Confirmation of the lead effect through the recording of compound muscle action potentials and electrocardiography - Implications for the interpretation of recorded potentials from humans -
-
- Hashimoto Shuji
- Department of Neurology, Tenri Hospital Department of Internal Medicine, Shirakawa Branch, Tenri Hospital
-
- Segawa Yoshiaki
- Laboratory of Neurophysiology, Nishinomiya Kyoritsu Neurosurgery Hospital
Bibliographic Information
- Other Title
-
- 複合筋活動電位(CMAP)と心電図(ECG)記録によるリード線効果の検証
Search this article
Description
<p>INTENTION: A lead in this study means an electric wire connected to an electric circuit at one point. Every part of a lead is equipotential because of the absence of current. This equipotentiality is termed the lead effect. We investigated through the recording of compound muscle action potentials (CMAPs) and electrocardiography (ECG) whether this characteristic nature of the lead is applicable in the human body. METHODS: First, we recorded CMAPs from two male persons connected to each other. Stimulation was delivered to subject 1 alone and subject 2 assumed the role of a lead. CMAPs of subject 1 were recorded from the abductor pollicis brevis muscle with the belly-tendon method. While subject 2 was touching the belly area of subject 1 with his right index finger, the potential was led from the left forearm of subject 2 with a reference on the tendon area of subject 1. When subject 2 was touching the tendon area, the potential was recorded from the belly area of subject 1 with a reference on the left forearm of subject 2. Second, we recorded ECG simultaneously from the two subjects connected to each other by their hands. RESULTS: The recording from the left forearm of subject 2 demonstrated potentials almost identical to the CMAPs of subject 1. This suggested that the potential at the area of subject 1 touched by subject 2 was ‘transmitted’ without significant alteration to the left forearm of subject 2, which was far from the generator of the CMAP. ECG activity of one person was also ‘transmitted’ to another. CONCLUSION: This study suggested that the human body works well as a lead. An area far away from a generator can register some potential through the lead or lead-like structure, such as extremities, and does not necessarily constitute an inactive site.</p>
Journal
-
- Tenri Medical Bulletin
-
Tenri Medical Bulletin 25 (1), 14-21, 2022-12-25
Tenri Foundation, Tenri Institute of Medical Research