REVERSE POWER FLOW OPERATION EFFECT OF HOUSEHOLD FUEL CELL CO-GENERATION SYSTEM IN AN APARTMENT HOUSE
-
- ITAMI Yuri
- Former Graduate School of Human-Environment Studies, Kyushu Univ.
-
- SUMIYOSHI Daisuke
- Facility of Human-Environment Studies, Kyushu Univ.
Bibliographic Information
- Other Title
-
- 集合住宅における家庭用燃料電池コージェネレーションシステムの逆潮流運転効果
Description
<p>We calculated the difference of energy saving effect of household fuel cells between with and without reverse power flow in an apartment. In order to calculate, we created the simulation model by using measured data of the equipment’s operating conditions and energy demands in an apartment house where reverse power flow occurred. It was clarified that the household’s primary energy reduction rate by fuel cell was improved by 6.9%pt on average by performing reverse power flow, and the effect was high in apartments with a large hot water supply load with respect to the power load.</p>
Journal
-
- Journal of Environmental Engineering (Transactions of AIJ)
-
Journal of Environmental Engineering (Transactions of AIJ) 87 (799), 588-596, 2022-09-01
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390293268648760064
-
- ISSN
- 1881817X
- 13480685
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- OpenAIRE
-
- Abstract License Flag
- Disallowed