Surface Tension Measurement of Molten Metal using A Falling Droplet in A Short Drop Tube

この論文をさがす

説明

A drop tube-type short time microgravity system was developed to measure the surface tension of high temperature melts using an oscillating drop method. The oscillation of a falling droplet was precisely recorded using the combination of a line sensor and a laser backlight. The surface oscillation of the droplet was quite simple during the falling, and consequently, the surface tension was calculated using Rayleigh's equation. The measurements were carried out over a wide temperature range including the undercooling state. The obtained surface tension of copper is expressed as below. γ=1257-0.20 (T-1356) (mN/m) (T:1287K-1998K)

収録刊行物

  • Transactions of JWRI

    Transactions of JWRI 34 (2), 29-33, 2005-12

    大阪大学接合科学研究所

詳細情報 詳細情報について

  • CRID
    1390294252778950528
  • NII論文ID
    120004841294
  • NII書誌ID
    AA00867058
  • DOI
    10.18910/7099
  • HANDLE
    11094/7099
  • ISSN
    03874508
  • 本文言語コード
    en
  • 資料種別
    departmental bulletin paper