Clarification of Refrigerant Boiling Behavior in an Evaporator Utilizing Neutron Imaging

Bibliographic Information

Other Title
  • 中性子イメージングを活用した蒸発器内における冷媒沸騰挙動の解明
  • サイエンス記事 中性子イメージングを活用した蒸発器内における冷媒沸騰挙動の解明
  • サイエンス キジ チュウセイシ イメージング オ カツヨウ シタ ジョウハツキ ナイ ニ オケル レイバイフットウ キョドウ ノ カイメイ

Search this article

Description

<p>For downsizing of an evaporator used for a car air conditioning, comprehension of refrigerant boiling behavior is required. Because the evaporator is generally made from metal material (e.g. aluminum), there is no way to visualize refrigerant boiling state directly until now. Although numerical simulation and thermoviewer analysis allow estimation of the boiling state, but not enough. We are trying to visualize refrigerant boiling state directly by utilizing neutron imaging, from view points following: Constituent metal material of the evaporator and gas refrigerant are transparent for neutron beam, on the other hand, liquid refrigerant can intercept the neutrons. In this paper, our case study of neutron imaging for refrigerant boiling in an evaporator is disclosed.</p>

Journal

  • hamon

    hamon 28 (2), 94-98, 2018-05-10

    The Japanese Society for Neutron Science

References(1)*help

See more

Details 詳細情報について

Report a problem