EFFECTS OF SHAPE OF ROUGHENED CONCRETE BY CHIPPING ON SHEAR STRENGTH FOR EXISTING BUILDING

Bibliographic Information

Other Title
  • 既存コンクリートのチッピングによる目荒らしの凹凸形状がせん断耐力に及ぼす影響
  • キソン コンクリート ノ チッピング ニ ヨル メ アラシ ノ オウトツ ケイジョウガセン ダンタイリョク ニ オヨボス エイキョウ

Search this article

Abstract

<p>In seismic retrofitting of existing building, concrete surface are chipped using an electric chipping hammer in order to connect retrofitting members to R/C frames. The roughened concrete surface has very complex concavo-convex shape. Therefore, estimating of the shear strength is very difficult. <br>In this paper, we conducted the shape-measurement and shape-analysis of roughened concrete. In addition, the shear tests are also conducted. Using the obtained data, we tried to evaluate the shear strength as sum of strength by bearing stress and by local interlocking. As a result, it was concluded that the optimal area ratio rcr was about 0.3.</p>

Journal

References(2)*help

See more

Details 詳細情報について

Report a problem