- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Refractive Index Measurement of Dental Materials by Swept-source Optical Coherence Tomography
-
- Kazuko YOSHIKAWA
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry
-
- Yu KATAOKA
- Department of Conservative Dentistry, Division of Oral Biomaterials and Engineering, Showa University School of Dentistry
-
- Mikihiro KOBAYASHI
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry
-
- Mai YAMAGUCHI
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry
-
- Hiromi OGAWA
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry
-
- Takashi MIYAZAKI
- Department of Conservative Dentistry, Division of Oral Biomaterials and Engineering, Showa University School of Dentistry
-
- Atsufumi MANABE
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry
Bibliographic Information
- Other Title
-
- 波長掃引光干渉断層装置 (SS-OCT) による歯科材料の光屈折率の測定
Search this article
Description
<p> Purpose: The aim of this study was to examine the clinical efficacy of swept-source optical coherence tomography (SS-OCT) for measuring the refractive index of metal-free restoration materials, for which accurate measurements are difficult to obtain by conventional refractometry.</p><p> Methods: Twenty-five specimens with dimensions of 10×10×1.0 mm (vertical×side×thickness) were used, consisting of five specimens each of five types of material: ESTELITE BLOCK (EB), IPS Empress CAD (IEP), IPS e-max CAD (IEM), VITA SUPRINITY for KaVo ARCTICA (VS), and NACERA pearl 1 (NA). Eight areas on each specimen were randomly selected as measuring points. The refractive index was calculated from the optical path length (OPL) and the actual thickness obtained by the OPL matching method. The mean refractive index was then calculated based on the data from each type of metal-free restoration material. To investigate whether the thickness of the specimen influenced the refractive index, simple regression analyses were performed.</p><p> Results: The refractive index of NA, which is difficult to measure by conventional refractometry, was 2.227 (±0.023), a significantly higher value (p<0.05) than that of the other materials (-1.5). All of the materials exhibited a negative correlation between the thickness and the refractive index by simple regression analysis.</p><p> Conclusion: Refractive index measurement of the metal-free restoration materials was possible via SS-OCT, including for NA (zirconia), which cannot be measured by conventional refractometry due to its high refractive index. In this study, we confirmed that the refractive index obtained by SS-OCT is influenced by the specimen thickness. It is suggested that by measuring the refractive index of the material in advance and digitizing the refractive index data, the actual thickness of the material can easily be measured at the chair-side. We suggest that SS-OCT has wide potential in clinical applications, not limited to its value as an imaging technique.</p>
Journal
-
- The Japanese Journal of Conservative Dentistry
-
The Japanese Journal of Conservative Dentistry 61 (6), 368-377, 2018
The Japanese Society of Conservative Dentistry
- Tweet
Details 詳細情報について
-
- CRID
- 1390564238060860032
-
- NII Article ID
- 130007543130
-
- ISSN
- 21880808
- 03872343
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed