Strength evaluation of metal roof cladding material failed at its edge
-
- Gavanski Eri
- Osaka City University
-
- Goda Riho
- Osaka City University
-
- Nishimura Hiroaki
- Association for Disaster Prevention Research
Bibliographic Information
- Other Title
-
- 金属屋根葺き材の端切れ破壊に対する耐力評価
Abstract
<p>As one of the causes of metal roofing failure due to wind loads, there is failure at the edge of metal roof panel or metal clip for fixing metal roof panel. MSRW 2014, which summaries the details of construction and maintenance methods for metal roof building components which are not covered in SSR 2007 and SSW 2011, presents the test methods and results in order to determine the metal panel strength for such failure. However, only 1 test specimen for each test parameter was employed in order to understand how this failure occurs and the effect of each parameter in general. Hence, the present study performs a similar test to determine the maximum resistance of metal panel under such failure but with more test specimens (min 5) for obtaining statistically reliable data as well as suggesting its estimation equations.</p>
Journal
-
- Summaries to Technical Papers of Annual Meeting, Japan Association for Wind Engineering
-
Summaries to Technical Papers of Annual Meeting, Japan Association for Wind Engineering 2019 (0), 165-166, 2019
Japan Association for Wind Engineering
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390564238099637504
-
- NII Article ID
- 130007662559
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed