Influence of Space Charge Accumulation by Pre-stress on Partial Discharge Inception Voltage

  • Mima Maimi
    Measurement and Electric Machine Control Labs., Tokyo City University
  • Narita Tokihiro
    Measurement and Electric Machine Control Labs., Tokyo City University
  • Miyake Hiroaki
    Measurement and Electric Machine Control Labs., Tokyo City University
  • Tanaka Yasuhiro
    Measurement and Electric Machine Control Labs., Tokyo City University
  • Kozako Masahiro
    Hikita and Kosako Labs., Kyushu Institute of Technology
  • Hikita Masayuki
    Hikita and Kosako Labs., Kyushu Institute of Technology

Bibliographic Information

Other Title
  • 前課電による空間電荷蓄積が部分放電開始電圧へ与える影響
  • ゼン カデン ニ ヨル クウカン デンカ チクセキ ガ ブブン ホウデン カイシ デンアツ エ アタエル エイキョウ

Search this article

Description

<p>Space charge accumulation characteristics in PAI (polyamide-imide), which are used as an insulating layer of motor windings, were observed under applying a rectangular voltage. Furthermore, PDIV (partial discharge inception voltage) in twisted pair wires coated with PAI was also measured by applying the rectangular voltage previously applied with a dc voltage (prestress), which generates the space charge. Since a change of PDIV was observed in the prestressed sample, it was concluded that the space charge accumulation may affect the change of PDIV.</p>