Investigation of Ductile Fracture Mechanism in Multipass Drawing of Hollow Specimen

DOI DOI Web Site Web Site Web Site View 1 Remaining Hide 1 Citations 16 References Open Access

Bibliographic Information

Other Title
  • 中空材の引抜き加工における延性破壊メカニズム検討
  • チュウクウザイ ノ ヒキヌキ カコウ ニ オケル エンセイ ハカイ メカニズム ケントウ

Search this article

Description

<p>To apply hollow forming technology for car parts, it is necessary to understand the ductile fracture mechanism of hollow forming. In this study, the cold drawing test and the finite element method analysis (FEM) of hollow specimens were carried out. It was clarified that the ductile fracture of hollow specimens in cold drawing was affected by both stress triaxiality and Lode angle parameter. As a result of fracture observation of a hollow specimen, an equiaxed dimple and an elongated dimple were observed. A mixed-mode ductile fracture mechanism (shear deformation of voids and typical void growth and coalescence) for hollow specimens in cold drawing is assumed.</p><p> </p><p>This Paper was Originally Published in Japanese in J. JSTP 61 (2020) 33–39.</p>

Journal

  • MATERIALS TRANSACTIONS

    MATERIALS TRANSACTIONS 62 (4), 505-511, 2021-04-01

    The Japan Institute of Metals and Materials

Citations (1)*help

See more

References(16)*help

See more

Report a problem