Limit Operating Frequency of Peak Current Mode Control DC-DC Converter Considering Turn-Off Delay Time
-
- FUJIWARA Kazuya
- Kyushu University
-
- UTE Ryo
- Kyushu University
-
- IMAOKA Jun
- Kyushu University
-
- SHOYAMA Masahito
- Kyushu University
Bibliographic Information
- Other Title
-
- ターンオフ遅延時間を考慮したピーク電流モード制御DC-DCコンバータの限界動作周波数
Abstract
Peak current mode control is a widely used control method for DC-DC converter because it has higher stability and responsibility. However, if the switching frequency is increased without careful consideration on the turn-off delay time, it may become the frequency dividing operation. In this operation, the switching frequency is not equal to the clock frequency and can not drive with high switching frequency. In this paper, we clarified the mechanism of the frequency dividing operation and derived the relationship between the turn-off delay time and the limit operating frequency. Also, we derived the relationship when we applied the slope compensation as well.