Role of lower intensity part of exercise on linearity between oxygen uptake and work rate during incremental exercise in ramp function

DOI HANDLE Web Site オープンアクセス

この論文をさがす

抄録

The oxygen uptake (VO_2) response to ramp-fashion loading of cycle ergometer shows linearity to work rate (WR), although additional VO_2 is observed during high-intensity exercise of step protocol. This additional VO_2 is reportedly reduced by prior exercise. We tested the hypothesis that the existence of the initial half of ramp exercise, which is assumed as prior exercise, affects the VO_2 in the high-intensity part of ramp exercise to bring the linearity. Seven males (24+3 yrs, 174+5 cm, 66+5 kg) performed two bouts of incremental ramp exercise (1W increase every 6-second). In the control trial, the exercise started from 0 W, while in the experimental trial, it started from the work rate (range: 112-200 W) corresponding to the individual ventilatory threshold (Tvent). Breath-by-breath VO_2 was measured in two repetitions for each trial. The VO_2-WR relationship was calculated from the data above Tvent, using the same work rate range in each subject. A regression analysis revealed that the slope of VO_2 to a given WR was significantly steeper in the experimental trial than in the control trial (VO_2 (ml/min) =10.7 WR (W) + 382 in control; VO_2 = 11.9 WR +244 in experimental; p<0.05). Result implies that the warm-up-like effect of. the initial ramp half reduces the slow component of VO_2, consequently responsible for the linear increase in VO_2 during incremental ramp exercise.

収録刊行物

  • 健康科学

    健康科学 28 7-13, 2006-03-25

    九州大学健康科学センター

詳細情報 詳細情報について

問題の指摘