Irregular antibody screening using fully automatic blood transfusion test device Erytra Eflexis
-
- KATOU Chiaki
- Department of Medical Technique, Nagoya University Hospital
-
- WATANABE Juri
- Department of Medical Technique, Nagoya University Hospital
-
- MATSUOKA Hiroki
- Department of Medical Technique, Nagoya University Hospital
-
- ENDOU Hiroko
- Department of Medical Technique, Nagoya University Hospital
-
- WATANABE Tomomi
- Department of Medical Technique, Nagoya University Hospital
-
- MATSUSHITA Tadashi
- Department of Transfusion, Department of Clinical Laboratory Medicine, Nagoya University Hospital
Bibliographic Information
- Other Title
-
- 全自動輸血検査装置Erytra Eflexisを用いた不規則抗体スクリーニング
- ゼン ジドウ ユケツ ケンサ ソウチ Erytra Eflexis オ モチイタ フキソク コウタイ スクリーニング
Search this article
Abstract
<p>A fully automatic blood transfusion test device can prevent dispensing errors, eliminate individual differences in agglutination judgment, and minimize labor saving. We conducted a basic study of irregular antibody screening by the gel column agglutination method (Gel-CAT) using the fully automatic blood transfusion test device Erytra Eflexis®. The device was not affected by abnormal levels of colours routinely encountered in chylothorax, hemolysis, and hyperbilirubinemia. It was only affected by a high immunoglobulin level at IgG 7,371 mg/dL in the low-ionic-strength solution indirect antigulobulin test (LISS-IAT) and in specimens that produced rouleaux formation in the enzymatic method using papain. In the comparison of Gel-CAT with the glass-bead-based column agglutination method (Glass-CAT) using this device, Gel-CAT showed strong reaction intensity with anti-Kidd, anti-Duffy, and anti-Diego antibodies in LISS-IAT, and both anti-e and anti-Dia antibodies were detectable only by Gel-CAT. In the enzymatic method, Gel-CAT showed a strong reaction intensity with anti-Rh, anti-Kidd, and anti-Lewis antibodies, and three anti-Rh antibodies and two anti-Kidd antibodies were detected only by Gel-CAT. In samples with early antibody production, anti-E antibodies were detected earlier by Gel-CAT with the enzymatic method using papain. Gel-CAT detected anti-Jkb, anti-Dia, and anti-Lea antibodies similarly to PEG-IAT. Gel-CAT was particularly effective in detecting anti-Rh antibodies. For anti-D antibodies, the detection sensitivities were 0.02 IU/mL for LISS-IAT and 0.01 IU/mL for the enzymatic method using papain. Therefore, we concluded that Eflexis is useful for routine tests.</p>
Journal
-
- Japanese Journal of Medical Technology
-
Japanese Journal of Medical Technology 71 (1), 87-94, 2022-01-25
Japanese Association of Medical Technologists
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390572321594241152
-
- NII Article ID
- 130008144458
-
- NII Book ID
- AN10229989
-
- ISSN
- 21885346
- 09158669
-
- NDL BIB ID
- 032532555
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- CiNii Articles
-
- Abstract License Flag
- Disallowed