NON-CONTACT RIVER DISCHARGE MEASUREMENT IN UPSTREAM RIVER USING RADIO CURRENT METER
-
- ONDA Minoru
- 前橋工科大学
-
- HIRAKAWA Ryuichi
- 前橋工科大学
-
- OHNO Tomohiro
- 国土交通省関東地方整備局
-
- KASHIWADA Jin
- パシフィックコンサルタンツ株式会社
-
- YAMASAKI Yusuke
- パシフィックコンサルタンツ株式会社
-
- INOUE Takuya
- 株式会社水文環境
-
- ABE Akihiro
- 株式会社水文環境
Bibliographic Information
- Other Title
-
- 河川上流部での非接触型流速計測法を用いた高水流量観測の実用化
Abstract
<p>In the present study, to build a river-discharge measurement system without floats in upstream, we have attempted to apply a radio current meter in a flood-flow measurement in Tone River. The observed results indicate that the water-surface velocity using a radio current meter has an influence of the wind. However, the measurement accuracy of the velocity using a radio current meter considered by the effect of wind are good agreements with those of ADCP. It is noteworthy that the coefficient of float show increasing and decreasing trend as water depth and the averaged coefficient of float are as same as the standard value. Therefore we can apply the standard value of the coefficient of float to the velocity using a radio current meter.</p>
Journal
-
- Advances in River Engineering
-
Advances in River Engineering 21 (0), 95-98, 2015
Japan Society of Civil Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390573242800297600
-
- ISSN
- 24366714
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
-
- Abstract License Flag
- Allowed