STUDY FOR MAINTENANCE OF CABLE COVERED WITH POLYETHYLENE UNDER CORROSION ENVIRONMENT

DOI

Bibliographic Information

Other Title
  • 内部が腐食環境下にあるPE 被覆ケーブルの維持管理方法に関する検討

Abstract

<p>It is not clear how to take measures other than replacing when the cable covered with polyethylene is damaged for some reason and the inside of cable is in a corrosive environment. In this paper, we examine the effect of various methods for improving the corrosive environment using an actual cable with high humidity inside the cable. As a result, it is found that it is necessary to induce clear air flow in order to dehumidify inside the cable which consists of a large number of wires. And if the polyethylene is not damaged and sealed,there is a high possibility that the entire inside the cable can be dehumidified by air supply drying using the air supply holes and the exhaust holes provided at the bottom of the cable.</p>