PERFORMANCE EVALUATION OF RESIDENTIAL HEAT-PUMP WATER HEATERS (PART 2): ENERGY CONSUMPTION ESTIMATION METHOD BASED ON HEAT-PUMP COP, STORAGE HEAT LOSS AND AUXILIARY POWER LOSS

Bibliographic Information

Other Title
  • 家庭用ヒートポンプ給湯機のエネルギー消費性能評価に関する研究(その2):ヒートポンプ効率,貯湯熱損失,補機電力損失に基づくエネルギー消費量推定方法の考案

Search this article

Description

<p>The purpose of this study was to develop a method for estimating the energy consumption of residential CO2 refrigerant heat-pump water heaters. This paper considered a calculation model involving the use of actual machine data analyzed in Part 1. It was evaluated by considering the effect of efficiency losses on the ideal system COP. The calculation model estimated "heat-pump COP", "storage heat loss" and "auxiliary power loss". The developed method was applicable to wide-ranging hot water supply conditions. The estimation and test values of the system COP agreed to within a tolerance of around ±0.2.</p>

Journal

References(3)*help

See more

Details 詳細情報について

Report a problem