Examination of anticoagulant performance of airless hemodialysis circuit Arch Loop

  • Kamiyama Takuma
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Yamaguchi Takeshi
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Nozawa Yusuke
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Arisaka Yasuhiro
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Fujiwara Shinri
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Akaki Show
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Oyamada Ryo
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Kaneko Yoshiro
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Sasaki Yumi
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Aida Takanobu
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Murayama Mio
    Faculty of Clinical Engineering, Dokkyo Medical University Nikko Medical Center
  • Ueno Asuka
    Department of Cardiovascular Medicine & Nephrology, Dokkyo Medical University Nikko Medical Center
  • Hoshiai Megumi
    Department of Cardiovascular Medicine & Nephrology, Dokkyo Medical University Nikko Medical Center
  • Horie Yasuto
    Department of Cardiology, Dokkyo Medical University Nikko Medical Center
  • Sugimura Hiroyuki
    Department of Cardiology, Dokkyo Medical University Nikko Medical Center
  • Yasu Takanori
    Department of Cardiovascular Medicine & Nephrology, Dokkyo Medical University Nikko Medical Center
  • Kawamoto Shinya
    Department of Cardiovascular Medicine & Nephrology, Dokkyo Medical University Nikko Medical Center

Bibliographic Information

Other Title
  • エアレス透析用回路「アーチループ」の抗凝固性能に関する検討
  • エアレス トウセキヨウ カイロ 「 アーチループ 」 ノ コウギョウコ セイノウ ニ カンスル ケントウ

Search this article

Description

<p>[Background and Aims] Blood coagulation in the dialysis circuit is one of the major problems in hemodialysis. Contact between air and blood is considered to contribute to activation of the coagulation system. Nikkisoʼs new dialysis circuit Arch Loop is expected to exhibit anticoagulant performance by reducing contact with air through an air-free chamber and a diaphragm pressure-monitoring system. We examined the effectiveness of Arch Loop in terms of anticoagulant performance compared with conventional dialysis circuits. [Method] Twelve outpatients on maintenance hemodialysis were enrolled in the study to investigate anticoagulant performance, measuring the activated clotting time (ACT) at 3 hours after the start of dialysis using Arch Loop or a conventional dialysis circuit, with a crossover design. [Results] ACT was significantly extended with Arch Loop compared with conventional circuits. (165.1±19.0 and 153.2±15.2 seconds, respectively, p<0.002). [Conclusion] Arch Loop shows significant anticoagulant performance by reducing contact with air in the circuit. This performance of Arch Loop is still limited, and so further improvement is required prior to general use.</p>

Journal

References(4)*help

See more

Details 詳細情報について