Study on Fast Deuteron Diagnostics Method Using Fast 3He Visible Spectra in the Large Helical Device Deuterium Plasma
-
- KIMURA Kento
- Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University
-
- MATSUURA Hideaki
- Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University
-
- ITOH Chujo
- Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University
-
- KAWAMOTO Yasuko
- National Institute for Fusion Science, National Institutes of Natural Sciences
-
- OISHI Tetsutaro
- National Institute for Fusion Science, National Institutes of Natural Sciences Department of Fusion Science, The Graduate University for Advanced Studies, SOKENDAI
-
- GOTO Motoshi
- National Institute for Fusion Science, National Institutes of Natural Sciences Department of Fusion Science, The Graduate University for Advanced Studies, SOKENDAI
-
- OGAWA Kunihiro
- National Institute for Fusion Science, National Institutes of Natural Sciences Department of Fusion Science, The Graduate University for Advanced Studies, SOKENDAI
-
- NISHITANI Takeo
- Graduate School of Engineering, Nagoya University
-
- ISOBE Mitsutaka
- National Institute for Fusion Science, National Institutes of Natural Sciences Department of Fusion Science, The Graduate University for Advanced Studies, SOKENDAI
-
- OSAKABE Masaki
- National Institute for Fusion Science, National Institutes of Natural Sciences Department of Fusion Science, The Graduate University for Advanced Studies, SOKENDAI
書誌事項
- タイトル別名
-
- Study on Fast Deuteron Diagnostics Method Using Fast <sup>3</sup>He Visible Spectra in the Large Helical Device Deuterium Plasma
この論文をさがす
説明
<p>Fast ion diagnostic is one of the most crucial plasma diagnostics for nuclear fusion investigation. A new diagnostic method for fast ions has been proposed using visible spectra of 3He produced by a deuteron-deuteron reaction. This diagnostic method has a better energy resolution than methods using neutron/γ-ray and is superior to conventional spectroscopy in measuring high energy (MeV order) ions. This diagnostic method has been predicted using numerical analysis for ITER, but no verification experiments have been performed yet. In this study, we examined the measurability of this diagnostic method in the large helical device (LHD) deuterium plasma. Although very dependent on the measurement geometry and the spectrometer performance, it may be possible to measure the fast 3He visible spectrum.</p>
収録刊行物
-
- Plasma and Fusion Research
-
Plasma and Fusion Research 18 (0), 1403002-1403002, 2023-01-30
一般社団法人 プラズマ・核融合学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390576502656058624
-
- NII書誌ID
- AA12346675
-
- ISSN
- 18806821
-
- HANDLE
- 10655/00013545
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- IRDB
- Crossref
- KAKEN
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可