書誌事項
- タイトル別名
-
- Development of visualization technology for transmission oil behaviour using X-ray computed tomography
抄録
<p>In the development of transmissions for automobiles, it is necessary to understand the oil behavior and incorporate it into the initial design so that oil lubrication can be performed appropriately. For that purpose, it is important to visualize the oil behavior under various usage environments and establish a model-based development utilizing fluid simulation. However, there is a limit to the conventional method of making visualization holes and investigating local oil behavior. In this research, in order to solve this problem, we have developed a device that combines a medical X-ray computed tomography (CT) and a drive tilting device, and succeeded in visualizing the oil behavior in three dimensions.</p>
収録刊行物
-
- 年次大会
-
年次大会 2022 (0), S111-02-, 2022
一般社団法人 日本機械学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390577043838060928
-
- ISSN
- 24242667
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
-
- 抄録ライセンスフラグ
- 使用不可