Experimental Study on Ignitability of R290/Air Premixture by an Arc Discharge at the Gap of Electric Contacts
-
- IMAMURA Tomohiko
- Department of Mechanical and Electrical Engineering, Suwa University of Science
この論文をさがす
説明
<p>The ignitability of the R290/air mixture by arc discharge at the gap of the electric contacts was experimentally examined. A series of ignition tests were conducted by opening and closing a pair of electric contacts, and the voltage between the anode and cathode, and the current through the circuit were measured. The varieties of electric load, power consumption of the circuit, and composition of the R290/air mixture were varied under the experimental conditions. The ignition frequency showed an upward convex curve against the equivalence ratio, and it was taken maximum value near ϕ = 1.3 (approximately 5 vol% of C3H8). It was easier to ignite when the electrical contacts were opened than when they were closed. It was also observed that ignition occurred more easily with increased power consumption. The minimum energy generated at the gap of the electric contact in the case of ignition (Earc m ) was much larger than the minimum ignition energy (Emin). This was because the contribution rate of energy available for ignition was much smaller than in the case of capacitive spark ignition. The net energy contributing to ignition (Econt) is less than 6% of the Earc m at most because go or no-go of ignition can be distinguished well by comparing and Econt(=0.006Earc m). This almost coincides with the data reported in the literature.</p>
収録刊行物
-
- 日本冷凍空調学会論文集
-
日本冷凍空調学会論文集 advpub (0), 193-204, 2023
公益社団法人 日本冷凍空調学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390579289378183040
-
- NII書誌ID
- AA11125910
-
- ISSN
- 2185789X
- 13444905
-
- NDL書誌ID
- 033278604
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
-
- 抄録ライセンスフラグ
- 使用不可