<p> St.ThomasⅡcrystalloid cardioplegia(CCP)を用いた長時間間隔の心筋保護の安全性は確立されていない。本研究は低侵襲僧帽弁手術を受ける患者を対象にSt.ThomasⅡCCPを60分間間隔で投与した場合の安全性を、blood cardioplegia(BCP)と比較して評価した。低侵襲僧帽弁手術を行った症例97件を対象とした。BCP 30分間隔(B群)とCCP 60分間隔(C群)に分け、propensity score matching(PSM)にて交絡因子の調整を行い、術後のCK-MBを比較検討した。Max.CK-MBはB群:58U/L vs. C群:37U/L(p=0.168)と両群間に有意差はなかった。St.ThomasⅡCCPは、60分の投与間隔でもBCPと同等の心筋保護効果が得られる可能性が示唆された。</p>