Cell Recovery by Exposure to Titanium and Zirconium Ions

DOI

Bibliographic Information

Other Title
  • チタンならびにジルコニウムイオン曝露による細胞回復度の影響

Abstract

<p>Titanium and zirconium have almost no biological problems, and have been widely used in recent dental clinics for implants and aesthetic dentistry. It is necessary to further investigate the biological risks when titanium and zirconium are ionized from the surface and affect surrounding tissues for various reasons in vivo. Therefore, we conducted an investigation using a cell recovery test method in which the toxicity level is determined from the recovery of cells, in which the culture medium to which the material was exposed is removed and then returned to the environment of fresh culture medium. Zirconium ions showed a greater level of cell recovery than titanium ions. Although titanium and zirconium have been shown to have excellent biological safety, when they are ionized in the body due to mechanical stimulation, they are not necessarily biologically safe and secure materials like other metal ions. There is a possibility that this may occur, and further multifaceted biological studies are considered necessary.</p>

Journal

Details 詳細情報について

  • CRID
    1390581224765227392
  • DOI
    10.11223/jard.22.30
  • ISSN
    18800815
    13489615
  • Text Lang
    en
  • Data Source
    • JaLC
  • Abstract License Flag
    Disallowed

Report a problem