Evaluations about factor of effective concrete width of RC column- S beam joints with a cover plate in shearing capacity
-
- XU Xu
- Dept. of Architecture, Faculty of Engineering, Maebashi Institute of Technology
-
- KITANO Atsunori
- Dept. of Architecture Faculty of Engineering, Maebashi Institute of Technology
Bibliographic Information
- Other Title
-
- ふさぎ板形式の鉄筋コンクリート柱・鉄骨梁構造柱梁接合部せん断耐力におけるコンクリート有効幅係数に関する検討
Abstract
<p>The effective concrete width of 13 beam-through type reinforced concrete column-steel beam joints with a cover plate was analyzed in this study, it was found that the factor of effective concrete width of test specimens decreased with the increase of column-to-beam width ratio when the column-to-beam ratio was less than 3.2. Based on the analysis, the factor of effective concrete width was proposed, and it was found that the shear strength of the test specimens is better agreement with test results than AIJ Recommendations for Design Mixed Structurers Composed of Reinforced Concrete Columns and Steel Beams and formula proposed by Sakaguchi Noboru.</p>
Journal
-
- Journal of Structural Engineering B
-
Journal of Structural Engineering B 70B (0), 273-279, 2024
Architectural Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390581224765271424
-
- ISSN
- 24366285
- 09108033
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
-
- Abstract License Flag
- Allowed