書誌事項
- タイトル別名
-
- STANDARIZATION OF THE TARGET VOLUME FOR THE CONFORMATION RADIOTHERAPY OF CANCER OF THE MAXILLARY SINUS
- ジョウガク ゲンタイ ショウシャ ニ オケル セン スガタ ノ ヒョウジュンカ
この論文をさがす
説明
Conformation mechanism is capable of fitting the high dose region to the shape and size of any tumor. In case of the conformation radiotherapy for cancer of the maxillary sinus, the shapes of the target volume and the transverse section of the patient's face are considerably constant in every patients. The axial transverse tomograms of the maxillary sinus in 52 cases with cancer of the maxillary sinus were traced and the shape of the target volume was decided on each case. From these procedures it was found out, that the shape of the transverse section of the patient's face can be substituted by the long oval of Haynes's with the maximal difference of 3 mm (about 3% difference of the TPR). Three kinds of cam (small, middle and large size) were prepared on the practical application of this method, because the figure of the transverse section of the patient could be also classified three kinds of long oval of Haynes. The TPR and the dose can be easily calculated from these standardized figures.
収録刊行物
-
- 日本放射線技術学会雑誌
-
日本放射線技術学会雑誌 33 (3), 238-244, 1977-09-01
公益社団法人 日本放射線技術学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390845702273452928
-
- NII論文ID
- 110003460607
-
- NII書誌ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- NDL書誌ID
- 1845755
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可