Pre-charge Method Using a Bi-directional Isolated DC-DC Converter
-
- Iyasu Seiji
- SOKEN, INC.
-
- Hayashi Yuji
- SOKEN, INC.
-
- Handa Yuichi
- DENSO Corporation
-
- Nakamura Kimikazu
- DENSO Corporation
-
- Wada Keiji
- Tokyo Metropolitan University
Bibliographic Information
- Other Title
-
- 双方向絶縁型DC-DCコンバータを用いたプリチャージ方法
- ソウホウコウ ゼツエンガタ DC-DC コンバータ オ モチイタ プリチャージ ホウホウ
Search this article
Description
<p>This paper proposes a capacitor pre-charge method using a bi-directional isolated DC-DC converter. This converter topology works as a phase-shifted full bridge DC-DC converter under forward direction of power conversion. In addition, this converter topology works as a current-fed converter under backward direction of power conversion and can operate in both the buck-mode and boost-mode. Then, a switching control method is presented for the voltage critical area of buck-boost. Appropriate input current control can be achieved by this switching control method in the voltage critical mode of buck-boost. Finally, the effectiveness of this pre-charge method is verified through an experiment on pre-charge using a 200V, 1000µF capacitor.</p>
Journal
-
- IEEJ Transactions on Industry Applications
-
IEEJ Transactions on Industry Applications 139 (10), 863-872, 2019-10-01
The Institute of Electrical Engineers of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390845702294116992
-
- NII Article ID
- 130007722393
-
- NII Book ID
- AN10012320
-
- ISSN
- 13488163
- 09136339
-
- NDL BIB ID
- 030010354
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed