Output Behaviors of the ACM Sensor for Condensation
-
- Suzuki Tomoyasu
- Syrinx Co., Ltd
-
- Ono Takaya
- Syrinx Co., Ltd
-
- Takahashi Satoru
- College of engineering, Shibaura Institute of Technology
-
- Noda Kazuhiko
- College of engineering, Shibaura Institute of Technology
Bibliographic Information
- Other Title
-
- 結露によるACMセンサの出力挙動
- 第65回材料と環境討論会 講演大会論文 結露によるACMセンサの出力挙動
- ダイ65カイ ザイリョウ ト カンキョウ トウロンカイ コウエン タイカイ ロンブン ケツロ ニ ヨル ACM センサ ノ シュツリョク キョドウ
Search this article
Abstract
<p>Various tests were conducted to reveal the relationship between the output behaviors of the Atmospheric Corrosion Monitor (ACM) sensor and the amount of corrosion from condensation that occurs as a physical phenomenon. As the sensor output at the time of condensation differs from the behavior when it is wet due to rain or water absorption of adhered sea salt, it was necessary to separately evaluate the behavior. As a result, in the respective phenomena, a relationship was confirmed between the sensor output and the amount of corrosion obtained by measurement in situ. Therefore, this may enable prediction of corrosion speed in a short period using the output of the ACM sensor.</p>
Journal
-
- Zairyo-to-Kankyo
-
Zairyo-to-Kankyo 68 (5), 112-115, 2019-05-10
Japan Society of Corrosion Engineering
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390845702303594240
-
- NII Article ID
- 130007732494
-
- NII Book ID
- AN10235427
-
- ISSN
- 18819664
- 09170480
-
- NDL BIB ID
- 029739646
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed