Development of Oxygen Concentration Control System for Chick Embryo Body Movement Measurement

DOI

Bibliographic Information

Other Title
  • ニワトリ胚体動計測のための任意酸素濃度制御システムの開発

Abstract

The purpose of this study is to develop a control system of an arbitrary oxygen (O2) concentration with quick responses and high accurate control.We used Arduino and Processing to create a system. Both of them are very similar to the C language and the knowledge of it learned so far can be utilized.In the control of the electromagnetic valve, a method is adopted in which the setting of the pulse width is determined for each target oxygen concentration.As a result, we could control the average arrival time and average recovery time within 1 minute and control the variation to within ± 0.1%.In the future research, we need to more data of the characteristic body movement patterns in the hypoxic environment by using our O2-concentration control system.

Journal

Details 詳細情報について

  • CRID
    1390845713037307136
  • NII Article ID
    130007542655
  • DOI
    10.12792/iiae2018.012
  • ISSN
    2424211X
  • Text Lang
    ja
  • Data Source
    • JaLC
    • Crossref
    • CiNii Articles
  • Abstract License Flag
    Disallowed

Report a problem

Back to top