<p>A series of pullout tests was conducted to evaluate the tensile capacity of single post-installed anchors in low strength concrete. This study focused on application of bonded anchors which were installed on a half-scale RC slab made using low strength concrete with brick chips for coarse aggregate representing Bangladeshi concrete. This paper reports the pullout test results of five types of anchor specimens with different diameters and embedment lengths. The experimental tensile capacity of all specimens was higher than calculation using equations in Japanese guidelines, indicating that Japanese guidelines conservatively estimate the tensile capacity of bonded anchors in Bangladeshi concrete. </p>