Direct Measurement of Heat Transfer Coefficient Distribution around the Rewetting Front during High Temperature Surface Liquid Cooling
-
- Yamagata Keisuke
- The University of Electro-Communications
-
- Enoki Koji
- The University of Electro-Communications
-
- Okawa Tomio
- The University of Electro-Communications
Bibliographic Information
- Other Title
-
- 高温面液体冷却時におけるリウェッティングフロント近傍での熱伝達率計測
Description
<p>In order to elucidate the rewetting phenomenon in detail, it is important to know the distribution of the heat transfer coefficient in the vicinity of the rewetting front. However, the distribution of the heat transfer coefficient is not yet known in detail, and there are few data that directly measured its distribution. In this study, the temperature distribution of the wall surface temperature when the liquid film flows down was measured using a high-speed infrared camera, and the distribution of heat transfer coefficient was directly measured from the temperature data. We tried to experimentally determine the dominant factors influencing the heat transfer coefficient by changing experiment parameters.</p>
Journal
-
- The Proceedings of the Thermal Engineering Conference
-
The Proceedings of the Thermal Engineering Conference 2018 (0), 0039-, 2018
The Japan Society of Mechanical Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390845713064567808
-
- NII Article ID
- 130007637556
-
- ISSN
- 2424290X
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed