Interobserver Variability of Epicardial Adipose Tissue Thickness Measurements by Echocardiography
-
- Hirata Yukina
- Ultrasound Examination Center, Tokushima University Hospital
-
- Nishio Susumu
- Ultrasound Examination Center, Tokushima University Hospital
-
- Harada Osamu
- Clinical laboratory center, Kanto Central Hospital of the Mutual Aid Association of Public School Teachers
-
- Miyazato Naomi
- Clinical laboratory center, Shonan Hospital
-
- Harakuni Atsushi
- Clinical laboratory center, Shonan Hospital
-
- Kusunose Kenya
- Department of Cardiovascular Medicine, Tokushima University Hospital
-
- Ito Nobuhiko
- Department of Cardiovascular Medicine, Kanto Central Hospital of the Mutual Aid Association of Public School Teachers
-
- Yamada Hirotsugu
- Department of Community Medicine for Cardiology, Tokushima University Graduate School of Biomedical Sciences
-
- Sata Masataka
- Department of Cardiovascular Medicine, Tokushima University Hospital
Bibliographic Information
- Other Title
-
- 超音波検査を用いた心外膜下脂肪厚の検査者間誤差の検討
Search this article
Description
<p>Purpose: Epicardial adipose tissue (EAT) is ectopic fat surrounding the coronary arteries. Our previous study reported that EAT in the anterior interventricular groove (EAT-AIG) can be visualized and used as a marker of coronary artery disease. This study was conducted at a single center; thus, it was not a multicenter validation study. Here we conducted a multicenter trial to determine interobserver variability of EAT-AIG measurements.</p><p>Subjects and Methods: To examine the interobserver variability, three sonographers at different cardiovascular hospitals measured the EAT-AIG thickness in 12 volunteers (mean age: 61±22 years, 8 males). The measurement of EAT-AIG thickness was performed using a linear ultrasound probe (Vivid E9). To measure EAT-AIG thickness, we used a modified low parasternal long-axis view. EAT-AIG thickness was measured as the distance from the myocardium to the visceral layer of the epicardium, perpendicular to the pericardium. All sonographers were blinded to each other’s interpretation. We used Bland–Altman analysis and the intraclass correlation coefficient (ICC) to determine the variation of EAT-AIG thicknesses among the three sonographers.</p><p>Results and Discussion: There was a good correlation between all of the measurements. The measurements of EAT-AIG thickness by the three sonographers were highly correlated (ICC: 0.90, 95% confidence interval: 0.78–0.97, p<0.01). However, we found one case which we determined to be an outlier. The outlier measurement of EAT-AIG thickness was measured in the apical view and not in the modified low parasternal long-axis view.</p><p>Conclusions: Echocardiographic measurements of EAT-AIG thickness significantly varied, with linear measurements showing the least variability among the three sonographers. These findings should considered when evaluating the clinical and scientific significance of longitudinal, repeated measurements of EAT-AIG thickness.</p>
Journal
-
- Japanese Journal of Medical Ultrasound Technology
-
Japanese Journal of Medical Ultrasound Technology 44 (4), 456-463, 2019-08-01
Japanese Society of Sonographers
- Tweet
Details 詳細情報について
-
- CRID
- 1390845713087095296
-
- NII Article ID
- 130007690587
-
- DOI
- 10.11272/jss.290
-
- ISSN
- 18814514
- 18814506
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed