Improvement of Electrochemical Conditions for Detecting Redox Reaction of K<sub>3</sub>[Fe(CN)<sub>6</sub>] toward the Application in Norovirus Aptasensor
-
- HIRANO Seiya
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University
-
- SAITO Junki
- Department of Applied Chemistry, School of Engineering, The University of Tokyo
-
- YUKAWA Tomoki
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University
-
- SANO Daisuke
- Department of Frontier Science for Advanced Environment, Graduate School of Environmental Studies and Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University
-
- OKAMOTO Akihiro
- International Center for Materials Nanoarchitectonics (WPI-MANA) and Center for Sensor and Actuator Material, National Institute for Materials Science (NIMS) School of Chemical Sciences and Engineering, Hokkaido University
-
- OKABE Satoshi
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University
-
- KITAJIMA Masaaki
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University
Abstract
<p>Electrochemical biosensors have attracted significant attention as a novel tool for the sensitive detection of pathogens and contaminants, with the potential capability of rapid, on-site diagnosis. In this study, we intended to improve the sensitivity of electrochemical biosensor using Fe(CN)63−/4− as redox marker, toward its application to norovirus aptasensors. Although many researchers have developed electrochemical aptasensors for various analytes using redox markers, the reported electrochemical conditions under which an aptasensor was examined varied across multiple studies. Here, we performed square-wave voltammetry (SWV) for electrodes modified with aptamer specific to murine norovirus and compared the reduction peak currents of Fe(CN)63− under various conditions. Effects of working electrode materials and NaCl and [Ru(NH3)6]Cl3 concentration in the electrolyte were examined. Among conditions we tested, the best sensitivity was obtained using a screen-printed gold electrode in an electrolyte containing 1 M NaCl with 4 mM K3[Fe(CN)6], in which the concentration of murine norovirus showed linearity with SWV peak current. This study provided useful information on the electrochemical measurement conditions regarding the development of electrochemical aptasensors.</p>
Journal
-
- Electrochemistry
-
Electrochemistry 88 (3), 205-209, 2020-05-05
The Electrochemical Society of Japan
- Tweet
Details
-
- CRID
- 1390848250109880832
-
- NII Article ID
- 130007840220
-
- ISSN
- 21862451
- 13443542
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Allowed