Corrosion Model of Carbon Steel Pipe on Manhole

Bibliographic Information

Other Title
  • 地下に建設されたマンホール環境における鋼管内面腐食速度モデル
  • チカ ニ ケンセツ サレタ マンホール カンキョウ ニ オケル コウカン ナイメン フショク ソクド モデル

Search this article

Abstract

<p>Many facilities were built underground to maintain communication, and they have been feared that corrosion of the inner surface of a steel pipe may cause failure in cable laying or reduct the seismic performance. To obtain long-term corrosion rate, a specimen made of steel pipe was placed in a manhole that is assumed to be close to the actual environment, and the corrosion rate was measured by inspecting the weight loss over four years. In addition to this, the specimen are observed with SEM and analyzed with XPS. There are some dense layers on specimen consist of FeOOH, Fe3O4, Fe(OH)2CO3. Because of dense layer, corrosion rate can be proportional to 1/2 power of time. The coefficients of the model equation were determined from the measured values.</p>

Journal

  • Zairyo-to-Kankyo

    Zairyo-to-Kankyo 68 (11), 321-325, 2019-11-10

    Japan Society of Corrosion Engineering

References(1)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem