Outline of “AIJ Design Guidelines for Lateral Load-carrying Capacity Calculation of Prestressed Concrete Buildings(Draft)”
-
- Maruta M.
- 静岡理工科大学 理工学部建築学科
-
- Shimazaki K.
- 神奈川大学 工学部建築学科
Bibliographic Information
- Other Title
-
- 日本建築学会「プレストレストコンクリート造建築物の保有水平耐力計算指針(案)・同解説」の概要
- ニホン ケンチク ガッカイ 「 プレストレスト コンクリートゾウ ケンチクブツ ノ ホユウ スイヘイ タイリョク ケイサン シシン(アン)・ ドウ カイセツ 」 ノ ガイヨウ
Search this article
Abstract
<p>“Design Guidelines for Lateral Load-carrying Capacity Calculation of Prestressed Concrete Buildings(Draft)” has been published by Architectural Institute of Japan in 2020. Many PC buildings were designed using the revised seismic design method in 1981. However, there is no guideline from AIJ about its design method of PC structures. The characteristic of this guideline that a damage control design for the 1st level and a safety design for the 2nd level, are clearly shown. The members have to be designed serviceability limit at the 1st level. And the lateral load-carrying capacity calculation for the assumed hinge mechanism of a building, are carried out at the 2nd level.</p>