書誌事項
- タイトル別名
-
- Surge Voltage Reduction Method for Dual Active Bridge Matrix Converter Using Circulating Current
- カンリュウ デンリュウ オ リヨウ シタ DAB マトリックスコンバータ ノ サージ デンアツ テイゲンポウ
この論文をさがす
説明
<p>This paper proposes an extended method of zero-voltage switching (ZVS) range for a dual active bridge (DAB) matrix converter with a discontinuous current mode (DCM). In the traditional DAB converter, ZVS cannot be achieved at a light load condition. The duty ratio calculation to achieve power factor correction and ZVS is explained using a circulating current. From the experimental results using a 5-kW prototype, the ZVS operation with zero transmission power is achieved by increasing the circulating current. In addition, the grid current distortion is lower than 5.0% at the rated power regardless of the DC voltage variation of plus or minus 20%.</p>
収録刊行物
-
- 電気学会論文誌D(産業応用部門誌)
-
電気学会論文誌D(産業応用部門誌) 141 (8), 591-597, 2021-08-01
一般社団法人 電気学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390851862122838912
-
- NII論文ID
- 130008070560
-
- NII書誌ID
- AN10012320
-
- ISSN
- 13488163
- 09136339
-
- NDL書誌ID
- 031639463
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可