STUDY ON FROST DAMAGE RANGE OF SLAB TRACK FILLING LAYER
-
- TAKAHASHI Takatada
- (公財)鉄道総合技術研究所 軌道技術研究部
-
- MISAWA Yoshifumi
- 元(公財)鉄道総合技術研究所 軌道技術研究部
-
- SAITO Shigehiko
- 山梨大学 大学院総合研究部
Bibliographic Information
- Other Title
-
- スラブ軌道てん充層の凍害範囲に関する基礎的研究
Abstract
<p> Frost damage, which is thought to be caused by freezing and thawing, has occurred in some of the slab track filling layers. Although previous investigations have confirmed that the frost damage range is wider at the corners than at the sides, the cause of this damage has not been fully elucidated. In this study, temperature change tests were conducted on slab track specimen to measure the temperatures inside the filling layer. As a result, it was confirmed that the freezing range of the corner was wider than that of the side. As a result of reproducing the temperature change of the specimen by unsteady heat conduction analysis using finite element analysis, it was clarified that the freezing range of the corner spreads due to the influence of the temperature transmitted from the side and end faces of the specimen. In addition, unsteady heat transfer analysis was also performed for the analytical model of the slab track, and the range of the filling layer that may be subject to frost damage was indicated.</p>
Journal
-
- Journal of Japan Society of Civil Engineers, Ser. E1 (Pavement Engineering)
-
Journal of Japan Society of Civil Engineers, Ser. E1 (Pavement Engineering) 78 (2), I_219-I_226, 2023
Japan Society of Civil Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390858143389631360
-
- ISSN
- 21856559
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
-
- Abstract License Flag
- Disallowed