EXPERIMENTAL STUDY ON TENSILE CHARACTERISTICS OF POST-INSTALLED ADHESIVE ANCHOR EMBEDDED IN WALL

Bibliographic Information

Other Title
  • 既存壁式鉄筋コンクリート造建築物において下階壁面内に施工される接着系あと施工アンカーの引張特性に関する実験的研究

Abstract

<p>For the renovation of the reinforced concrete boxed-wall building, a new opening would be constructed on multi-story wall frame, and local retrofit with post-installed adhesive anchors would be applied. In this study, evaluation method of tensile strength for a post-installed adhesive anchor embedded in wall plane was proposed. The non-fixed bond-tensile test of anchor specimens embedded in wall-slab specimen was conducted. The parameter of specimens are embedment length of anchors, wall thickness, and wall shapes. Tensile strength of the anchors could be evaluated due to previous formula with the assumption of the effect of local retrofit on bottom floor wall and floor slab.</p>