Inter-rater Reliability and Cost in Pricing for Creating Dataset Focused on Mediolateral Oblique View in Mammography

Bibliographic Information

Other Title
  • マンモグラフィ内外斜位撮影の臨床画像評価を対象としたアノテーション付与における評価者間信頼性と人的負荷

Abstract

<p>Purpose: The purpose of this study was to assess inter-rater reliability and workload for creating accurate training data in the clinical evaluation of mammographic positioning for deep learning. Methods: A total of 107 mammographic images without lesions were labeled by two certified radiologic technologists in seven items: six clinical image evaluation criteria in positioning and breast tissue density. The kappa coefficient was calculated as an indicator of interrater reliability. Furthermore, the labeling cost per image was calculated based on labeling time and salary for the technologists. Results: The kappa coefficients were 0.71 for inframammary fold, 0.43 for nipple in profile, 0.45 for great pectoral muscle, 0.10 for symmetrical images, and 0.61 for retromammary fat. No significant difference was found in the coefficients of spread of breast tissue. The cost per image was calculated at 11.0 yen. Conclusion: The inter-rater reliability for the inframammary fold, nipple in profile, great pectoral muscle, and retromammary fat ranged from “moderate” to “substantial.” The reliability for symmetrical images was “slight,” indicating the need for a consensus among evaluators during labeling. The labeling cost was equivalent to or higher than that of existing services.</p>

Journal

References(13)*help

See more

Details 詳細情報について

Report a problem

Back to top